14 research outputs found
Microtesla MRI of the human brain combined with MEG
One of the challenges in functional brain imaging is integration of
complementary imaging modalities, such as magnetoencephalography (MEG) and
functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive
superconducting quantum interference devices (SQUIDs) to directly measure
magnetic fields of neuronal currents, cannot be combined with conventional
high-field MRI in a single instrument. Indirect matching of MEG and MRI data
leads to significant co-registration errors. A recently proposed imaging method
- SQUID-based microtesla MRI - can be naturally combined with MEG in the same
system to directly provide structural maps for MEG-localized sources. It
enables easy and accurate integration of MEG and MRI/fMRI, because microtesla
MR images can be precisely matched to structural images provided by high-field
MRI and other techniques. Here we report the first images of the human brain by
microtesla MRI, together with auditory MEG (functional) data, recorded using
the same seven-channel SQUID system during the same imaging session. The images
were acquired at 46 microtesla measurement field with pre-polarization at 30
mT. We also estimated transverse relaxation times for different tissues at
microtesla fields. Our results demonstrate feasibility and potential of human
brain imaging by microtesla MRI. They also show that two new types of imaging
equipment - low-cost systems for anatomical MRI of the human brain at
microtesla fields, and more advanced instruments for combined functional (MEG)
and structural (microtesla MRI) brain imaging - are practical.Comment: 8 pages, 5 figures - accepted by JM
In vivo Observation of Tree Drought Response with Low-Field NMR and Neutron Imaging
Using a simple low-field NMR system, we monitored water content in a livingtree in a greenhouse over two months. By continuously running thesystem, we observed changes in tree water content on a scale of halfan hour. The data showed a diurnal change in water content consistentboth with previous NMR and biological observations. Neutron imaging experiments showthat our NMR signal is primarily due to water being rapidly transported through the plant, and not to other sources of hydrogen, such as water in cytoplasm, or water in cell walls. After accountingfor the role of temperature in the observed NMR signal, we demonstratea change in the diurnal signal behavior due to simulated drought conditionsfor the tree. These results illustrate the utility of our system toperform noninvasive measurements of tree water content outside of a temperature controlled environment
Multi-Channel SQUID System for MEG and Ultra-Low-Field MRI
A seven-channel system capable of performing both magnetoencephalography
(MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described.
The system consists of seven second-order SQUID gradiometers with 37 mm
diameter and 60 mm baseline, having magnetic field resolution of 1.2-2.8
fT/rtHz. It also includes four sets of coils for 2-D Fourier imaging with
pre-polarization. The system's MEG performance was demonstrated by measurements
of auditory evoked response. The system was also used to obtain a multi-channel
2-D image of a whole human hand at the measurement field of 46 microtesla with
3 by 3 mm resolution.Comment: To appear in Proceedings of 2006 Applied Superconductivity Conferenc
Multi-sensor system for simultaneous ultra-low-field MRI and MEG
Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low
fields (ULF MRI) are two methods based on the ability of SQUID (superconducting
quantum interference device) sensors to detect femtotesla magnetic fields.
Combination of these methods will allow simultaneous functional (MEG) and
structural (ULF MRI) imaging of the human brain. In this paper, we report the
first implementation of a multi-sensor SQUID system designed for both MEG and
ULF MRI. We present a multi-channel image of a human hand obtained at 46
microtesla field, as well as results of auditory MEG measurements with the new
system.Comment: To appear in Proceedings of 15th International Conference on
Biomagnetis
SQUIDs in biomagnetism : A roadmap towards improved healthcare
This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 686865.Peer reviewedPublisher PD
Neutron Imaging at LANSCE—From Cold to Ultrafast
In recent years, neutron radiography and tomography have been applied at different beam lines at Los Alamos Neutron Science Center (LANSCE), covering a very wide neutron energy range. The field of energy-resolved neutron imaging with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as quantitative density measurements, was pioneered at the Target 1 (Lujan center), Flight Path 5 beam line and continues to be refined. Applications include: imaging of metallic and ceramic nuclear fuels, fission gas measurements, tomography of fossils and studies of dopants in scintillators. The technique provides the ability to characterize materials opaque to thermal neutrons and to utilize neutron resonance analysis codes to quantify isotopes to within 0.1 atom %. The latter also allows measuring fuel enrichment levels or the pressure of fission gas remotely. More recently, the cold neutron spectrum at the ASTERIX beam line, also located at Target 1, was used to demonstrate phase contrast imaging with pulsed neutrons. This extends the capabilities for imaging of thin and transparent materials at LANSCE. In contrast, high-energy neutron imaging at LANSCE, using unmoderated fast spallation neutrons from Target 4 [Weapons Neutron Research (WNR) facility] has been developed for applications in imaging of dense, thick objects. Using fast (ns), time-of-flight imaging, enables testing and developing imaging at specific, selected MeV neutron energies. The 4FP-60R beam line has been reconfigured with increased shielding and new, larger collimation dedicated to fast neutron imaging. The exploration of ways in which pulsed neutron beams and the time-of-flight method can provide additional benefits is continuing. We will describe the facilities and instruments, present application examples and recent results of all these efforts at LANSCE